Home > Manufacturers > Time Mark > Transformers & Trasnducers

Transformers & Trasnducers

Transformers & Trasnducers

276A-10

276A-10

276-Series, Transformers-and-Transducers

The Model 276A Current Transformer is a low-cost, open-frame type current transformer. For use with up to 8-gauge wire, and up to 40 amps on the primary. 2500VMRS insulation is standard. Frequency range is 25-400 Hz.

The Model 276A CT is CSA Certified.


276B-100

276B-100

276-Series, Transformers-and-Transducers

The Model 276B Current Transformer is a ring-type current transformer for currents from 50 to 1200 amps. The Model 276B has an accuracy rating of plus or minus 2% for 50-100 amp CT’s, and plus or minus 1% over 100 amps at 60 Hz. This CT also features a 25-400 Hz frequency range, #8-32 secondary terminals and mounting brackets. Polarity markings are stamped on the transformer.

The Model 276B is UL Recognized and CSA Certified.


276B3-100

276B3-100

276B3-Series, Transformers-and-Transducers

The Model 276B3 is a ring-type 3-phase transformer for currents from 50-1200 amps. Secondary terminals are #8-32, brass studs with one flatwasher, lockwasher and regular nut. Polarity markings are stamped on the transformer. Holes at the corners of the transformer case are for attaching a mounting plate (not supplied).


276C

276C

276C-Series, Transformers-and-Transducers

The Model 276C Current-Canceling Transformer monitors two of the three phases, and cancels the effect of the current signal in the third phase, which would otherwise cause a phase shift error. The Model 276C accepts input directly or from two standard current transformers (CTs), corrects for the third leg, and provides a single current output to the controller.

The Model 276C is UL Recognized and CSA Certified. For use with Models 421 or 422 in 3-phase applications.


2780-115

2780-115

2780-Series, Transformers-and-Transducers

The Model 2780 AC Current Transducer is designed to accept an AC current input, and provide a proportional DC voltage output. A linear transformer input is coupled to a solid-state output amplifier. The Model 2780 is powered by a 115 VAC source, and is socket-mounted for ease of use. Model 2780 Current Transducers can be used with computer and programmable controls to provide: motor and power control; supervisory data acquisition; load monitoring; feedback control; energy management.


C278

C278

278-Series, Transformers-and-Transducers

The Model 278 AC Current Transducer is designed to accept an AC current input, and provide a proportional DC output. A linear transformer input is coupled to a solid-state output amplifier. The Model 278 is powered by a 115 VAC source, and is socket-mounted for ease of use. Model 278 Current Transducers can be used with computer and programmable controls to provide: motor and power control; supervisory data acquisition; load monitoring; feedback control; energy management.


C278-230

C278-230

278-Series, Transformers-and-Transducers

The Model 278 AC Current Transducer is designed to accept an AC current input, and provide a proportional DC output. A linear transformer input is coupled to a solid-state output amplifier. The Model 278 is powered by a 115 VAC source, and is socket-mounted for ease of use. Model 278 Current Transducers can be used with computer and programmable controls to provide: motor and power control; supervisory data acquisition; load monitoring; feedback control; energy management.